| SIMATIC WINAC RTX 2005, SINGLE LICENSE F. 1 INSTALL., R-SW, SW AND DOCU. ON CD, LICENSE KEY ON FD, CLASS A, 3 LANGUAGES (D,E,F), EXECUTABLE UNDER WIN 2000/XP AND ARDENCE RTX, REFERENCE-HW: SIMATIC PC |
General information |
Product type designation | SIMATIC WinAC RTX 2005 incl. SP2 |
Firmware version | 4,3 |
Memory |
Work memory |
integrated | PC RAM can be used (non-paged memory) |
Load memory |
integrated RAM, max. | PC RAM can be used (non-paged memory) |
CPU processing times |
for bit operations, typ. | 0.004 µs; Typical |
for fixed point arithmetic, typ. | 0.003 µs; Typical |
for floating point arithmetic, typ. | 0.004 µs; Typical |
Reference platform | Pentium 4, 2.4 GHz |
CPU-blocks |
DB |
Number, max. | Limited only by available PC work memory |
Size, max. | 64 kbyte |
FB |
Number, max. | Limited only by available PC work memory |
Size, max. | 64 kbyte |
FC |
Number, max. | Limited only by available PC work memory |
Size, max. | 64 kbyte |
OB |
Size, max. | 64 kbyte |
Number of time alarm OBs | 1 |
Number of delay alarm OBs | 1 |
Number of cyclic interrupt OBs | 9 |
Number of process alarm OBs | 1 |
Nesting depth |
per priority class | 24 |
additional within an error OB | 24 |
Counters, timers and their retentivity |
S7 counter |
Number | 2 048 |
Retentivity |
— adjustable | Yes |
— lower limit | 0 |
— upper limit | 2 047 |
— preset | 8 |
Counting range |
— adjustable | Yes |
— lower limit | 0 |
— upper limit | 999 |
IEC counter |
present | Yes |
Type | SFB |
S7 times |
Number | 2 048 |
Retentivity |
— lower limit | 0 |
— upper limit | 2 047 |
— preset | 0 |
Time range |
— lower limit | 10 ms |
— upper limit | 9 990 s |
IEC timer |
present | Yes |
Type | SFB |
Data areas and their retentivity |
Retentivity without UPS and PS Extension Board | 128 KB with SIMATIC Microbox PC 427B and Panel PC 477B; other SIMATIC PCs on request |
Retentivity with UPS | all data |
Flag |
Number, max. | 16 kbyte |
of which retentive | MB 0 to MB 16383 |
Retentivity preset | MB 0 to MB 15 |
Number of clock memories | 8 |
Address area |
I/O address area |
Inputs | 16 kbyte |
Outputs | 16 kbyte |
Process image |
Inputs, adjustable | 8 kbyte |
Outputs, adjustable | 8 kbyte |
Inputs, default | 512 byte |
Outputs, default | 512 byte |
Subprocess images |
Number of subprocess images, max. | 15 |
Digital channels |
Inputs | 128 000 |
Outputs | 128 000 |
Analog channels |
Inputs | 8 000 |
Outputs | 8 000 |
Hardware configuration |
Number of operable FMs and CPs (recommended) |
FM | FM distributed: FM 350-1 / 350-2, FM 351, FM 352, FM 353, FM 355 / 355-2 |
CP, PtP | CP 340, CP 341 distributed |
CP, LAN | Over PC CP |
Submodules |
Number of submodules, max | 4 |
— of which PROFIBUS, max. | 4; CP 5611, CP 5611-A2, integrated PROFIBUS interface of the SIMATIC PC, CP 5613 CP, 5613-A2 |
Time of day |
Clock |
Hardware clock (real-time) | Yes |
retentive and synchronizable | Yes |
Clock synchronization |
supported | Yes |
to PC-CP, slave | Yes |
1. Interface |
Interface type | CP 5611, CP 5611-A2, integrated PROFIBUS interface of the SIMATIC PC |
Physics | RS 485 / PROFIBUS |
Isolated | Yes |
Number of simultaneously operable CPs, max. | 1 |
Protocols |
MPI | No |
PROFIBUS DP master | Yes |
PROFIBUS DP slave | No |
PROFIBUS DP master |
Number of connections, max. | 8 |
Transmission rate, max. | 12 Mbit/s |
Number of DP slaves, max. | 64 |
Services |
— PG/OP communication | Yes |
— Routing | Yes |
— Global data communication | No |
— S7 basic communication | No |
— S7 communication | Yes |
— Equidistance | Yes; Only in conjunction with isochronous mode |
— Isochronous mode | Yes |
— SYNC/FREEZE | Yes |
— Activation/deactivation of DP slaves | Yes |
— Direct data exchange (slave-to-slave communication) | Yes |
— DPV0 | Yes |
— DPV1 | Yes |
Address area |
— Inputs, max. | 16 kbyte |
— Outputs, max. | 16 kbyte |
User data per DP slave |
— Inputs, max. | 244 byte |
— Outputs, max. | 244 byte |
2. Interface |
Interface type | CP 5613, CP 5613-A2 |
Physics | RS 485 / PROFIBUS |
Isolated | Yes |
Number of simultaneously operable CPs, max. | 4 |
Protocols |
MPI | No |
PROFIBUS DP master | Yes |
PROFIBUS DP slave | No |
PROFIBUS DP master |
Number of connections, max. | 50 |
Transmission rate, max. | 12 Mbit/s |
Number of DP slaves, max. | 125 |
Services |
— PG/OP communication | Yes |
— Routing | Yes |
— Global data communication | No |
— S7 basic communication | No |
— S7 communication | Yes |
— Equidistance | Yes; Only in conjunction with isochronous mode |
— Isochronous mode | Yes |
— SYNC/FREEZE | Yes |
— Activation/deactivation of DP slaves | Yes |
— Direct data exchange (slave-to-slave communication) | Yes |
— DPV0 | Yes |
— DPV1 | Yes |
Address area |
— Inputs, max. | 16 kbyte |
— Outputs, max. | 16 kbyte |
User data per DP slave |
— Inputs, max. | 244 byte |
— Outputs, max. | 244 byte |
Isochronous mode |
Isochronous operation (application synchronized up to terminal) | Yes |
Equidistance | Yes |
Number of DP masters with isochronous mode | 2 |
User data per isochronous slave, max. | 128 byte |
shortest clock pulse | 2.2 ms; 2.2 ms without partial process image; 2.2 ms with partial process image |
Communication functions |
PG/OP communication | Yes |
Global data communication |
supported | No |
S7 basic communication |
supported | No |
S7 communication |
as server | Yes |
as client | Yes |
Number of connections |
overall | 64 |
usable for PG communication | |
— reserved for PG communication | 1 |
usable for OP communication | |
— reserved for OP communication | 1 |
S7 message functions |
Number of login stations for message functions, max. | 62 |
SCAN procedure | No |
Process diagnostic messages | Yes; Alarm_S |
Alarm 8-blocks | Yes |
Process control messages | No |
Test commissioning functions |
Status block | Yes |
Single step | Yes |
Status/control |
Status/control variable | Yes |
Forcing |
Forcing | No |
Diagnostic buffer |
present | Yes |
Number of entries, max. | |
— preset | 120 |
Hardware requirement |
Hardware required | PC with color monitor, keyboard, mouse or pointing device for Windows |
Processor |
Processor | Intel Pentium 400 MHz |
— Multi-processor system | Yes; Dual Pentium, CoreDuo, Core2Duo |
— Hyper-threading | Yes |
Memory |
Main memory, min. | 256 Mbyte |
Required memory on hard disk | 100 Mbyte |
Operating systems |
pre-installed operating system |
Windows NT 4.0 | No |
Windows 2000 | Yes; Professional, SP3 or higher |
Windows XP | Yes; Professional, SP1 and SP2 |
Windows XP Embedded | Yes; With the delivery image of the SIMATIC PC |
— supported HAL types under Windows XP | PC with single core processor without Hyper-Threading: ACPI-PC, ACPI uniprocessor PC; PC with multicore processors or Hyper-Threading: ACPI multiprocessor PC |
Configuration |
Configuration software |
STEP 7 | Yes; V5.3 SP3 or higher, Engineering Tools (optional) |
Programming |
Nesting levels | 8 |
Programming language |
— LAD | Yes |
— FBD | Yes |
— STL | Yes |
— SCL | Yes |
— CFC | Yes |
— GRAPH | Yes |
— HiGraph® | Yes |
Software libraries |
— Easy Motion Control | Yes |
Know-how protection |
User program protection/password protection | Yes |
Open Development interfaces |
CCX (Custom Code Extension) | Yes; With WinAC ODK V4.1 |
CMI (Controller Management Interface) | Yes; With WinAC ODK V4.1 |
SMX (Shared Memory Extension) | Yes; With WinAC ODK V4.1 |
— Inputs | 4 kbyte |
— Outputs | 4 kbyte |
last modified: | 03/13/2019 |